Information Parameters
10-16 Chapter 10
APW lookup - Offers the flexibility of storing and recalling part numbers. The average piece weight and part
description will be stored and recalled with the part number. Refer to page 3-15 for more details on setup
and page 4-4 for operation.
Apps Menu - Access the Application Menu to switch to another operating mode or the factory default mode.
Refer to page 3-21 for more details.
Modbus TCP/IP - Used to establish master-slave/client-server communication between intelligent devices.
Refer to page 8-36 for more details.
DATABASE RESET
A newly installed database must be initialized before it is recognized by the Model 672/675. P65010 can be
used to initialize a database option without having to default. An uninitialized database is evident by the
message “NewDB Opt'n” after saving and exiting the setup mode.
For a database option that has already been initialized, Database Reset will clear the database memory. If
Setup RAM is allocated at P60040, the parameter setup stored in the database option will not be erased by
the Database Reset. If Pile RAM is allocated at P60050, it will not be possible to reset the database without
defaulting. The message See P65001 will direct you to the Default All parameter.