TEST MODE FUNCTION
151
ON Phase
0.0 ~ 359.9º
Resolution
0.
17. Go to the OFF Phs setting and set the end phase
of the step. The Fixed indicates user-defined
degree.
OFF Phase
Free, Fixed
OFF Phase
0.0 ~ 359.9º
Resolution
0.1º
Example of Using
Sequence
Function
0V
+50V
+100V
+150V
Output On
Step0 Step1 Step2 Step3
10S
15S
20S
RUN
Hold
Const
Keep
Sweep
30S
Step0
Sweep
STOP
Output Voltage
The example above shows how to generate a test
procedure in DC-INT mode by each step.
Step No.
0
1
2
3
Step Time
30 S
10 S
15 S
20 S
DCV
0 V
50 V
100 V
150 V
2
nd
Setting
SP
KP
SP
CT
Term
---
CONTI
CONTI
HOLD