REMOTE CONTROL
129
Command
:OUTPut:SERies {ON|OFF}
Function
Sets CH1/CH2 as tracking series mode.
Example
:OUTPut:SERies ON
Sets CH1/CH2 as Tracking series mode.
Command
:OUTPut:PARallel {ON|OFF}
Function
Sets CH1/CH2 as tracking parallel mode.
Example
:OUTPut:PARallel ON
Sets CH1/CH2 as tracking parallel mode.
Command
TRACK<NR1>
Function
Selects the operation mode: independent, tracking
series, or tracking parallel.
NR1 0: Independent, 1: Series, 2: Parallel
Example
TRACK0 Selects the independent mode
Command
:LOAD[1|2]:CV {ON|OFF}
Function
Sets CH1/CH2 as Load CV mode.
Example
:LOAD2:CV ON
Sets CH2 as Load CV mode.
Command
:LOAD[1|2]:CC {ON|OFF}
Function
Sets CH1/CH2 as Load CC mode.
Example
:LOAD2:CC ON
Sets CH2 as Load CC mode.
Command
:LOAD[1|2]:CR {ON|OFF}