Function
Sets CH1/CH2 as Load CR mode.
Example
:LOAD2:CR ON
Sets CH2 as Load CR mode.
Command
:MODE[1|2]?
Function
Queries CH1 or CH2 work mode.
6 modes below:
SERiesPARallelINDE pendent
CV LoadCC LoadCR Load
Example
:MODE1?
Queries CH1 work mode.:
Command
:LOAD[1|2]: RESistor <NRf>
Function
Sets the Load CR level.
Description
<NRf>
1-1000
Example
:LOAD2: RESistor 100
Sets the Load CR level to 100Ωfor CH2.
Command
:LOAD[1|2]: RESistor?
Function
Queries the Load CR level.
Description
<NRf>
1-1000
Example
: LOAD2: RESistor?
Return the Load CR level for CH2.
Command
:DELAy[1|2]:CYCLEs {N|I}[,<value>]
Function
Sets the cycle number of Delay.