EasyManuals Logo

GW Instek GPP-1326 User Manual

GW Instek GPP-1326
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
REMOTE CONTROL
169
Command
:STATus:MEASurement:ENABle?
Function
Read the measurement enable status register.
Example
:STATus:MEASurement:ENABle?
Read the contents of the measurement enable
status register.
Command
:STATus:MEASurement:CONDition?
Function
Read the measurement condition status register.
Example
:STATus:MEASurement:CONDition?
Read the contents of the measurement condition
status register.
Command
:STATus:QUEStionable[:EVENt]?
Function
Read the questionable event status register.
Example
:STATus:QUEStionable?
Read the questionable event status register.
Command
:STATus:QUEStionable:CONDition?
Function
Read the questionable condition status register.
Example
:STATus:QUEStionable:CONDition?
Read the questionable condition status register.
Command
:STATus:QUEStionable:ENABle <NRf>
Function
Programs the questionable enable status register.
Description
<NRf>
256: CAL (Calibration summary enable
bit). Register is 16 bits. If <value> is
between 256 and 511, it is certainly
valid. If <value> is between 512 and
65,535, ensure Cal (bit8) is a valid
value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPP-1326 and is the answer not in the manual?

GW Instek GPP-1326 Specifications

General IconGeneral
BrandGW Instek
ModelGPP-1326
CategoryPower Supply
LanguageEnglish

Related product manuals