REMOTE CONTROL
117
:multi:delay
<NR2>
:multi:delay?
Sets or returns trigger delay time for currently
selected step in millisecond.
Parameter: 0ms ~ 1000ms
Example: :multi:delay 10m (10ms)
:multi:freq <NR2>
:multi:freq?
Sets or returns the frequency for the currently
selected step in Hz.
Parameter: 20 ~ 1/5/10MHz
Example: :multi:freq 1e3 (1kHz)
:multi:func
<NR1>
:multi:func?
Sets or returns measurement type for the currently
selected step.
Send parameter: LS, LP, Q, CS, CP, D, Z, PHASE,
RS, RP, X, G, B, Y, RDC
Return parameter: 1 (Z), 2 (Ls), 3 (Lp), 4 (Cs), 5
(Cp), 7 (Y), 8 (G), 9 (P), 10 (Q), 11 (D), 12 (Rs), 13
(Rp), 14 (B), 15 (X), 16 (Rdc)
Example: :multi:func ls (Series inductance)
:multi:hi-lim
<NR3>
:multi:hi-lim?
Sets or returns the higher test limit of the currently
selected step.
Example: :multi:hi-lim 10 (limit to 10.0)
:multi:lev <NR3>
:multi:lev?
Sets or returns the drive level for the currently
selected step in Voltage.
Parameter: 10mV ~ 2V (DC/AC≤3 MHz)
10mV ~ 1V (AC>3 MHz)
Example: :multi:lev 200m (200mV)
:multi:load
<filename>
Loads an existed file to run or edit.
Example: :multi:load demo (file name demo)
:multi:lo-lim
<NR3>
:multi:lo-lim?
Sets or returns the lower test limit of the currently
selected step.
Example: :multi:lo-lim 5 (limit to 5)