Power Supply | 100-240 VAC, 50/60 Hz |
---|---|
Protection Class | IP54 |
Parameter | TOC (Total Organic Carbon) |
Detection Limit | 0.1 mg/L |
Inlet Pressure | 0.2 to 6 bar |
Operating Temperature | 5 to 40 °C |
Storage Temperature | -20 to 60 °C |
Communication | 4-20 mA, Modbus, Ethernet, USB |
Weight | 25 kg |
Certifications | CE, UL |
Explains manual symbols (Info, Caution, Warning, Danger) and instrument labels.
Lists electrical, chemical, and ozone gas hazards associated with the system.
Covers general safety, electrical, chemical, gas, and sample stream precautions.
Details keypad functions, menu levels, and startup behavior.
Explains initial screen display, message priority, and menu access.
Describes using the Start Stop menu for operating the analyzer.
Allows access to reagent menus for installation and purging.
Details zero calibration, check, and program settings.
Details entering span adjust values and starting calibration/check cycles.
Covers typical data, features, and signal I/O.
Details optional features, reagent consumption, and analysis methods.
Overview of analysis and electronics enclosures.
Explains operating modes, configurations, and oxidation method.
Details sample injection methods and analysis types.
Lists power, gas, reagent, and sample connection requirements.
Covers precautions and steps for unpacking and installing the unit.
Details wiring specifications for power and signal terminals.
Covers carrier gas and reagent connection details.
Lists reagents, their stability, and consumption rates.
Details compounds and procedures for preparing calibration solutions.
Verifies mains supply, connects gas, and reconnects internal tubing.
Guides through checking oxidation phase simulate functions.
Provides instructions for using commissioning menus for programming.
Introduces Maintenance and Diagnostics menus and their functions.
Details simulating various process tests for diagnostics.
Used to configure system settings, to be modified only if necessary.
Lists system faults, their causes, and recommended remedies.
Lists system warnings, their causes, and recommended remedies.
Configures parameters for fault detection and reporting.
Provides a checklist for weekly maintenance tasks.
Lists recommended checks and part replacements for periodic service.
Lists typical consumable and spare parts for 2-year operation.
Details warranty coverage, validity requirements, and exclusions.
Provides instructions for connecting an Epson LX300 printer.
Explains programmable 4-20mA output modes: Direct, Stream, Full Multiplex.
Provides definitions for abbreviations and terms used in the manual.
Lists contact details for HACH Company and its subsidiaries.
Declares compliance with EMC, Pressure Equipment, and Machinery Directives.