Built-in Floor Standing
Type Indoor Unit
No less than
150mm
No less than 150mm
No less than 150mm
No less than
150mm
Front
Wall Top side
Air return
Air return
Check hole
Check hole
Air outlet
Air outlet
Air outlet
No less than
1000mm
No less than 1750mm
Ground
■ The condensate drainage pipe should be over 1% gradient. And it should be wrapped with heat insulation pipe.
Choice of Blowing Wind from Blower
(when using the high performance lter)
The blower is provided with a red terminal and a white terminal. The standard wind choice has been set before
delivery. When the use of optional components, such as the high performance lter, causes the static pressure
rising, change the connection of the connector mounted on the side of the control cabinet, as shown as follows.
Standard
static
pressure
Maximal
static
pressure
0 30
Yellow
Orange
Black
Blue
Yellow
Black
Blue
Red
One side of
control cabinet
One side of blower
connector,
white
White
Yellow
Black
Blue
Red
Yellow
Black
Blue
Red
White
Red
High-speed blowing wind
Standard blowing wind (at delivery)
One side of blower
■ The indoor units of this series are low pressure duct type. Please contact the professional design and
after-sales service people for the following items: calculate the heat load and the external static pressure,
choose the correct return outlet, air return pipe, air discharging outlet and air discharging pipe .
CAUTIONS