47
360
O
C Smart Air Flow
Cassette Type Indoor Unit
Units Power supply Indoor fan motor Power input (w)
Model Phase FQY Voltage
Volt.
range
MCA MFA
Output
(W)
FLA Cooling Heating
AB072MRERA 1 50/60 220 198~242 0.39 1.24 22 0.31 30 30
AB092MRERA 1 50/60 220 198~242 0.39 1.24 22 0.31 30 30
AB122MRERA 1 50/60 220 198~242 0.39 1.24 22 0.31 30 30
AB162MRERA 1 50/60 220 198~242 0.39 1.24 22 0.31 30 30
AB182MRERA 1 50/60 220 198~242 0.39 1.24 22 0.31 30 30
AB242MRERA 1 50/60 220 198~242 0.39 1.24 36 0.31 50 50
AB282MRERA 1 50/60 220 198~242 0.39 1.24 36 0.31 50 50
AB302MRERA 1 50/60 220 198~242 0.71 2.28 63 0.57 90 90
AB382MRERA 1 50/60 220 198~242 0.71 2.28 63 0.57 90 90
AB482MRERA 1 50/60 220 198~242 0.71 2.28 78 0.57 110 110
AB602MRERA 1 50/60 220 198~242 0.71 2.28 78 0.57 110 110
Symbols:
MCA: Min. circuit amps (A)
MFA: Max. fuse amps of circuit breaker
Output: Fan motor rated output (w)
FLA: Full load amps (A)
Note:
1. Voltage range
The units are applicable for the electrical systems where voltage supplied to unit is in the range.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA=1.25*FLA MFA≤4*FLA
4. Power supply uses the circuit breaker.
3.6 Electric characteristics