508
20.7 Electric characteristics
Units Power supply Indoor fan motor Power input (W)
Model Phase FQY Voltage Volt range MCA MFA Output (W) FLA Cooling Heating
AS072MGERA 1 50/60 220 198-242 0.21 0.66 40 0.165 71 71
AS092MGERA 1 50/60 220 198-242 0.21 0.66 40 0.165 71 71
AS122MGERA 1 50/60 220 198-242 0.21 0.66 40 0.165 71 71
AS162MGERA 1 50/60 220 198-242 0.21 0.66 40 0.165 71 71
AS182MGERA 1 50/60 220 198-242 0.25 0.8 40 0.2 94 94
AS242MGERA 1 50/60 220 198-242 0.25 0.8 40 0.2 94 94
Symbols:
MCA: Min. circuit amps (A)
MFA: Max. fuse amps of circuit breaker
W: Fan motor rated output (W)
FLA: Full load amps (A)
Notes:
1. Voltage range
The units are applicable for the electrical systems where voltage supplied to unit is in the range.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA=1.25*FLA MFA ≤4*FLA
4. Power supply uses the circuit breaker.