72
4.3 Dimension
SN Part Name
1 Connection port of gas pipe
2 Connection of liquid pipe
3 Wiring connection port of motor/
pumping motor
4 Connect drain pipe
5 Inlet grill
6 Outlet grill
7 Drain hose(Accessory)
When inlet grill is closed, the least
reserved space is 200mm
※
Decoration board620
Decoration board620
Pipe connection
diagram
Connect drain pipe
⑥
⑤
535(Gap betwwn
supending rod)
570(Indoor units)
590(Celing open)
Indoor units570
*At least 1500
Less than100
⑦
60
Space needed for
installation
*At least 1500
*At least 1500
*At least 1500
*Electric box maintenance window
600×600
*Electric box
Raisetolessthan
750
285
140
180
310
310
170
210
176
195
580
30 25
55
200
Adjustable(0-360)
Suspending
bolt
4-M8~M10
1
2
60
60
750
175
③
④
275
210
Less than 10
175
210
4-M3.2reserved hole
100
(Directinstallation)
60 580 60
Greater than 1000resreved space
Less than 2700 to the wall
(Installedathighplace)
90
90

Table of Contents