EasyManua.ls Logo

Haier AB072MRERA - Dimension

Haier AB072MRERA
651 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72
4.3 Dimension
SN Part Name
1 Connection port of gas pipe
2 Connection of liquid pipe
3 Wiring connection port of motor/
pumping motor
4 Connect drain pipe
5 Inlet grill
6 Outlet grill
7 Drain hose(Accessory)
When inlet grill is closed, the least
reserved space is 200mm
Decoration board620
Decoration board620
Pipe connection
diagram
Connect drain pipe
535(Gap betwwn
supending rod)
570(Indoor units)
590(Celing open)
Indoor units570
*At least 1500
Less than100
60
Space needed for
installation
*At least 1500
*At least 1500
*At least 1500
*Electric box maintenance window
600×600
*Electric box
Raisetolessthan
750
285
140
180
310
310
170
210
176
195
580
30 25
55
200
Adjustable(0-360)
Suspending
bolt
4-M8~M10
1
2
60
60
750
175
275
210
Less than 10
175
210
4-M3.2reserved hole
100
(Directinstallation)
60 580 60
Greater than 1000resreved space
Less than 2700 to the wall
Installedathighplace
90
90

Table of Contents

Related product manuals