499
High Wall Type
Indoor Unit
MODEL AS162MGERA AS182MGERA AS242MGERA
Cabinet
Cabinet coating type Plastic Plastic Plastic
Cabinet salt spray test duration Hour / / /
Control box IP class IP20 IP20 IP20
Construction
Sheet metal thickness / / /
Drain pan material PS PS PS
Drain pan insulation 15 15 15
Drain pump option No No No
Branch outlet option No No No
Indoor wall
Material Plastic Plastic Plastic
Thickness mm / / /
Double or single skin Single Single Single
Air lter
Material PP PP PP
Mesh 100 100 100
Pressure drop Pa 5 5 5
Piping
dimension
Liquid pipe mm 6.35 9.52 9.52
Gas pipe mm 12.7 15.88 15.88
Drain hose mm 16.8 16.8 16.8
Fresh air dimension mm / / /
Sound pressure level (H/M/L) dB(A) 41/36/33 43/39/34 48/39/37
Sound power level (H/M/L) dB(A) 52/47/44 54/50/45 59/50/48
Standard static pressure Pa 0 0 0
Indoor air ow (H/M/L) m
3
/h 600/462/415 800/640/576 800/640/576
Dimension (W*H*D) mm 938*187*265 1046*239*299 1046*239*299
Packing (W*H*D) mm 1016*304*360 1111*329*373 1111*329*373
Net weight kg 10.9 13 13
Gross weight kg 13.1 16.5 16.5
Nominal condition: indoor temperature (cooling): 27DB (°C)/19WB (°C), indoor temperature (heating): 20DB (°C)
Outdoor temperature (cooling): 35DB (°C)/24WB (°C), outdoor temperature (heating): 7DB (°C)/6WB (°C)
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated
sound intensity meter. It is a sound pressure noise level.