High Wall Type
Indoor Unit (N platform)
MODEL
AS122MNERA AS162MNERA AS182MNERA
AS122MFERA AS162MFERA AS182MFERA
Cabinet
Cabinet Coating Type Plastic Plastic Plastic
Cabinet Salt Spray Test
Duration
Hour / / /
Control Box IP Class IP20 IP20 IP20
Construction
Sheet Metal Thickness / / /
Drain Pan Material ABS ABS ABS
Drain Pan Insulation 15 15 15
Drain Pump Option no no no
Branch Outlet Option no no no
Indoor Wall
Material Plastic Plastic Plastic
Thickness mm / / /
Double or Single Skin Single Single Single
Air Filter
Material PP PP PP
Mesh 100 100 100
Pressure Drop Pa 5 5 5
Piping
dimension
Liquid pipe mm 6.35 6.35 6.35
Gas pipe mm 12.7 12.7 12.7
Drain hose mm 16.8 16.8 16.8
Fresh air dimension mm / / /
Sound pressure level (H/M/L) dB(A) 37/33/29 39/36/34 40/39/35
Sound power level (H/M/L) dB(A) 54/51/50 56/53/51 57/54/52
Standard static pressure Pa 0 0 0
Indoor air ow (H/M/L) m
3
/h 630/560/500 800/720/650 920/800/720
Dimension (W*H*D) mm 855/200/280 1115/243/336 1115/243/336
Packing (W*H*D) mm 954/279/355 1206/342/418 1206/342/418
Net weight kg 10.5 16.5 16.5
Gross weight kg 12.7 20.1 20.1
Nominal condition: indoor temperature (cooling): 27DB (°C)/19WB (°C), indoor temperature (heating): 20DB (°C)
Outdoor temperature (cooling): 35DB (°C)/24WB (°C), outdoor temperature (heating): 7DB (°C)/6WB (°C)
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated
sound intensity meter. It is a sound pressure noise level.