Machine mode of operation | Program run submode
4
148
HEIDENHAIN | MANUALplus 620 | User's Manual | 12/2017
Skip level
Before you can set and activate skip levels, you need to define
them in the program.
Further information: smart.Turn and DIN Programming User's
Manual
Setting a Skip level:
Select the Flow menu item
Select the Skip level menu item
The control opens the Set the skip level form.
Cycle parameters:
NR: Skip levels
If you enter the value 2 in the NR parameter and press the Save
soft key, the control sets and activates the skip level 2 and
refreshes the display field accordingly. Furthermore, the next time
the program is run, the NC blocks defined by the set or active skip
level will not be executed by the control.
Further information: "Machine data display", Page 102
You can set and activate more than one skip level
at a time by entering a string of numerals in the NR
parameter. The entry 159 sets/activates the skip levels
1, 5 and 9.
To deactivate the skip levels, program the NR parameter
without a value and press Save.
When setting and activating skip levels during program
run, please remember that the control will respond with
a delay due to the block scan.