EasyManua.ls Logo

HEIDENHAIN 548431-05 - Page 463

HEIDENHAIN 548431-05
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ICP programming | Contour elements – front face
6
HEIDENHAIN | MANUALplus 620 | User's Manual | 12/2017
463
Circular arc on front face
Programming a circular arc:
Select the arc’s direction of rotation
Enter the arc dimensions
Define the transition to the next contour element
Parameters:
XK, YK: Target point – End point of circular arc
XKi, YKi: Target point (incremental) – Distance between
starting point and Target point
P: Target point (in polar coordinates)
Pi: Target point – Distance between starting point and target
point (polar, incremental)
C: Target point (polar angle)
Ci: Target point (polar angle, incremental; reference: starting
point)
I, J: Center point of circular arc
Ii, Ji: Center point of circular arc (incremental) – Distance
between starting point and Center point in X and Z
PM: Center point of circular arc (polar)
PMi: Center point of circular arc – Distance between starting
point and Center point (polar, incremental)
CM: Center point of circular arc (polar angle)
CMi: Center point of circular arc (polar angle, incremental;
reference: starting point)
R: Radius
ANs: Angle – Tangential angle in the starting point
ANe: Angle – Tangential angle in the target point
ANn: Angle to the subsequent element
ANp: Angle to the previous element
F: Further information: "Machining attributes", Page 418
ICP generates a G102 or G103 in smart.Turn mode of operation.