Settings for fixed cycles and units
6: Simultaneously with Y
Coolant for new units (602010): Default value for coolant CLT
0: Without
1: Circuit 1 on
2: Circuit 2 on
G60 for new units (602011): Default value for protection zone G60
0: Active
1: Inactive
Safety clearance G47 (602012)
[mm]: Default value for safety clearance G47
Safety clearance G147 in plane (602013)
[mm]: Default value for safety clearance SCK
Safety clearance G147 in infeed direction (602014)
[mm]: Default value for safety clearance SCI
Oversize in X direction (602015)
[mm]: Default value for oversize (X) I
Oversize in Z direction (602016)
[mm]: Default value for oversize (Z) K
Direction of rotation for new units (602017): Default value for direction of rotation MD
M3
M4
Datum shift (602022)
On: The AWG generates a datum shift
Off: The AWG does not generate a datum shift
Front edge of chuck on main spindle (602018)
[mm]: Position of the front edge of chuck in Z direction for calculating the workpiece
datum
Front edge of chuck on counter spindle (602019)
[mm]: Position of the front edge of chuck in Z direction for calculating the workpiece
datum
Jaw width on main spindle (602020)
[mm]: Jaw width on the main spindle in Z direction for calculating the workpiece
datum
Jaw width on counter spindle (602021)
[mm]: Jaw width on the counter spindle in Z direction for calculating the workpiece
datum