ASSEMBLY AND ANCHORING
6-7MS 3000 • 9095-032A
6.4 Assembly of the mast
If work has to be stopped,
always complete the phase
being worked on. Tighten all the
bolts used for the last
attachment and switch off and
secure the main switch so that
the machine cannot be
operated.
As the assembly proceeds,
place the anchor tubes and
anchors as described in section
6.5
Note that the power supply
consists of
3 x 400 V + neutral + safety
earth.
The masts must always be
assembled vertically.
In winds of strengths above
12,5 m/s (6 Beaufort) the
machine may not be
assembled.
While a mast element is being
mounted, the emergency stop
switch must be activated.
1. Connect the power supply to the
machine. The power supply
connection is in the centre of the
platform.
Fig.6-9 Power supply socket