4-2 Trackspot User Manual
Lamp shuts
OFF
Fixture is
overheated.
(Another symptom:
Fan LED will flash
four times, pause,
and repeat.)
a. Check the air vents for
restricted air flow due to dust
and dirt.
b. Clean the fan and verify the fan
is working. For more
information, see “Cleaning the
Outer Surfaces” on page 3-9.
c. Reduce the ambient
temperature around your
fixture. Maximum ambient
temperature for Trackspot is
50° C (122° F).
If your fixture overheats, you must
unplug the fixture, wait for the
fixture to cool, then reconnect the
power supply to reset the fixture.
Aging lamp
Replace lamp with a new or
verified working lamp. For more
information, see “Replacing the
Lamp” on page 3-1.
Error tone (two
level beeping)
after the fixture
homes
Incorrect
personality switch
setting.
Verify that the personality switch
setting you chose for your control
mode is correct. For more
information, see “Personality
Switches” on page 2-3.
Gobo or color
wheel not homing.
a. Clean the sensor and homing
slot. For more information, see
“Removing the Color Wheel or
Gobo Wheel” on page 3-10.
b. Manually rotate the wheel and
note any contact between the
wheel and any other internal
component. If the wheel is
warped, contact High End
Systems customer service (see
“Getting Help” on page Intro-3).
If the wheel is not warped,
adjust the wheel clearance. For
more information, see
“Adjusting Wheel Clearance” on
page 3-12.
Table 4-1. Symptoms and Solutions
Problem Possible Cause Possible Solution