CA/CE-Series GigE Area Scan Camera·User Manual
20
7.3 Set Trigger Mode
The camera has 2 types of trigger mode, including internal trigger mode and external trigger mode.
The trigger mode principle and parameter setting are shown below.
Table 7-1 Trigger Mode Principle and Parameter
Acquisition Control >
Trigger Mode
The camera acquires images via its
internal signals.
Acquisition Control >
Trigger Mode
The camera acquires images via
external signals. These signals can
be software signal and hardware
signal, including software trigger,
hardware trigger, counter trigger
and frame grabber trigger.
You can set trigger mode as shown below.
Steps:
1. Click Acquisition Control > Trigger Mode.
2. Select Off or On as Trigger Mode.
Figure 7-4 Set Trigger Mode
Off refers to the internal trigger mode, and On refers to the external trigger mode.