CA/CE-Series GigE Area Scan Camera·User Manual
42
Make sure the input voltage is not from 1 VDC to 1.5 VDC as the electric status between these
two values are not stable.
The breakdown voltage is 30 VDC, and keep voltage stable.
9.1.2 Line 1 Opto-isolated Output Circuit
The Line 1 opto-isolated output circuit in camera I/O control is shown below.
Figure 9-3 Line 1 Internal Circuit
The maximum output current of Line 1 is 25 mA.
Logic 1
Output Level
Logic 0
Output Level
Internal
Logic
TDR TDF
Figure 9-4 Output Logic Level
Opto-isolated output electric feature is shown in below (when the external voltage is 3.3 VDC and
the external resistance is 1 K).