EasyManua.ls Logo

HikRobot CA Series - Line 1 Opto-Isolated Output Circuit

HikRobot CA Series
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CA/CE-Series GigE Area Scan Camera·User Manual
42
Parameter Name
Parameter Symbol
Value
Input Rising Delay
TDR
2.6 μs
Input Falling Delay
TDF
19.2 μs
Make sure the input voltage is not from 1 VDC to 1.5 VDC as the electric status between these
two values are not stable.
The breakdown voltage is 30 VDC, and keep voltage stable.
9.1.2 Line 1 Opto-isolated Output Circuit
The Line 1 opto-isolated output circuit in camera I/O control is shown below.
GPO Line 1+
Line 1-
Figure 9-3 Line 1 Internal Circuit
The maximum output current of Line 1 is 25 mA.
Logic 1
Output Level
Logic 0
Output Level
Internal
Logic
TDR TDF
Figure 9-4 Output Logic Level
Opto-isolated output electric feature is shown in below (when the external voltage is 3.3 VDC and
the external resistance is 1 K).

Table of Contents