CA/CE-Series GigE Area Scan Camera·User Manual
31
2. Enter proper value in Line Debouncer Time, and its range is from 1 μs to 1000000 μs.
Figure 7-20 Set Trigger Debouncer
7.6 Event Control
The event control function allows you to enable event messages and camera events like
Acquisition Start.
When Event Notification is set to Notification On, the camera can generate an event and transmit
a related event message to the computer whenever a specific situation occurs. You can set event
control as shown below.
Steps:
1. Click Event Control.
2. Select specific event in Event Selector, for example, Acquisition Start.
3. Select Notification On as Event Notification.
Figure 7-21 Set Event Control
7.7 Chunk Data Control
The chunk data control function allows you to generate supplementary image data and append
that data to every image that you acquire. You can set chunk data control as shown below.
Steps:
1. Click Chunk Data Control.