CA/CE-Series GigE Area Scan Camera·User Manual
47
Camera
Power Supply
Opt-Iso in
Camera Power
Ground
PWR VCC
I/O Ground
GND of PWR
GND of VCC
Switch
Figure 9-10 Line 0 Connecting to a Switch
9.2.2 Line 1 Wiring
When the camera uses Line 1 as output signal, wirings are different with different external devices.
PNP Device
Camera
Power Supply
Opt-Iso out
Camera Power
Ground
PWR VCC
Device Power
Supply
Signal Line
Device Power
Ground
PNP Device
I/O Ground
GND of PWR
GND of VCC
Figure 9-11 Line 1 Connecting to PNP Device
NPN Device
If the VCC of NPN device is 24 VDC, and it is recommended to use 1 KΩ to 4.7 KΩ pull-up resistor.
If the VCC of NPN device is 12 VDC, and it is recommended to use 1 KΩ pull-up resistor.
Camera Power
Supply
Opt-Iso out
Camera Power
Ground
PWR VCC
Device Power
Supply
Signal Line
Device Power
Ground
NPN Device
I/O Ground
GND of PWR
GND of VCC
Figure 9-12 Line 1 Connecting to NPN Device