CA/CE-Series GigE Area Scan Camera·User Manual
25
Figure 7-10 Counter Trigger Parameters
7.4.5 Set Action Command Trigger
When you need to use the function of action commands, you should set action command trigger
first.
Steps:
1. Click Acquisition Control > Trigger Selector.
2. Select Frame Burst Start as Trigger Selector, and On as Trigger Mode.
3. Select Action 1 as Trigger Source.
Figure 7-11 Set Action Command Trigger
For specific function of action commands, please refer to Section 7.8 Action Commands for details.
7.4.6 Set Anyway Trigger
When you need to use both hardware trigger and software trigger, you can set Anyway as Trigger
Source.