Table 10-1 Byte Number of Different Pixel Formats
Format
Byte Number
Mono 8, Bayer GB/GR/BG/RG 8
1
Bayer GR/GB/RG 12 Packed, Bayer BG/GR/RG
10 Packed, Mono 10 Packed, Mono 12 packed
1.5
Bayer GR/GB/RG 12, Bayer BG/GR/RG 10, YUV
4:2:2 (YUYV), YUV4:2:2 (YUYV) Packed
2
RGB 8, BGR 8
3
You can set pixel format as shown below.
Steps:
1. Click Image Format Control > Pixel Format.
2. Set Pixel Format according to actual demands.
Figure 10-5 Set Pixel Format
10.5 Set Test Pattern
The camera supports test pattern function. When there is exception in real-time image, you can
check whether image of test mode have similar problem to determine the reason. This function is
disabled by default, and at this point, the outputted image by the camera is real-time image. If this
function is enabled, the outputted image by the camera is test image.