CA/CE-Series GigE Area Scan Camera·User Manual
26
Steps:
1. Click Acquisition Control > Trigger Selector.
2. Select Frame Burst Start as Trigger Selector, and On as Trigger Mode.
3. Select Anyway as Trigger Source.
Figure 7-12 Set Anyway Trigger
7.5 Trigger Related Parameters
Under external trigger mode, you can set burst frame count, trigger delay, trigger cache enable,
trigger activation and trigger debouncer. Different trigger sources can set various trigger
parameters, and their relation is shown below.
Table 7-4 Trigger Source and Trigger Parameter
Trigger Source
Trigger Parameter
Software
Trigger
Hardware
Trigger
Counter
Trigger
Action
Command
Trigger
Any Trigger
Burst Frame Count
Support
Support
Support
Support
Support
Trigger Delay
Support
Support
Support
Support
Support
Trigger Cache Enable
Support
Support
Support
Support
Support
Trigger Activation
Not support
Support
Support
Not support
Support
Trigger Debouncer
Not support
Support
Support
Not support
Support
7.5.1 Set Burst Frame Count
Under external trigger mode, you can set burst frame count as shown below.