CA/CE-Series GigE Area Scan Camera·User Manual
36
The Line Inverter parameter is disabled by default.
8.2.2 Enable Strobe Signal
The strobe signal is used to directly output I/O signal to external devices when camera’s event
source occurs. You can enable strobe signal as shown below.
Steps:
1. Click Digital IO Control.
2. Select different output events as Line Source according to actual demands.
3. Enable Strobe Enable.
Figure 8-3 Set Line Source
For specific Line Source, please refer to following table for details.