Steps:
1. Click Acquisition Control > Acquisition Burst Frame Count.
2. Enter proper value according to actual demands. Its range is from 1 to 1023.
Figure 7-13 Set Burst Frame Count
When Acquisition Burst Frame Count is 1, it is in single frame trigger mode. When Acquisition
Burst Frame Count is larger than 1, it is in multi-frame trigger mode. If Acquisition Burst Frame
Count is n and when inputting 1 trigger signal, the camera stops acquiring images after exposing n
times and outputs n frame images. The sequence diagram of burst frame count is shown below.
Figure 7-14 Sequence Diagram of Burst Frame Count
7.5.2 Set Trigger Delay
From camera receiving signal and responding, this period is trigger delay. Its sequence diagram is