CA/CE-Series GigE Area Scan Camera·User Manual
23
Steps:
1. Click Digital IO Control.
2. Select Line 2 as Line Selector, and Input as Line Mode.
Figure 7-7 Set Line2 as Input Signal
3. Select Line 0, or Line 2 as Trigger Source. Here we take Line 0 as an example.
Figure 7-8 Set Hardware Trigger
7.4.4 Set Counter Trigger
The counter trigger provides frequency division to the external trigger signal. You can set counter
trigger as shown below.
Steps:
1. Click Acquisition Control > Trigger Selector.
2. Select Frame Burst Start as Trigger Selector, and On as Trigger Mode.
3. Select Counter 0 as Trigger Source.