CA/CE-Series GigE Area Scan Camera·User Manual
61
different color temperatures. Ideally, the proportion of R channel, G channel and B channel in the
white region is 1:1:1.
Table 10-4 White Balance Status Description
Analog Control >
Balance White
Auto
You need to set the R, G, B value
manually, between 1 and 4095.
1024 means ratio is 1.0
Analog Control >
Balance White
Auto
Automatic white balance once.
Adjust the white balance for a
certain amount of time then stop. It
implements an algorithm that finds
possible gray areas in the Bayer
data.
Analog Control >
Balance White
Auto
Continuous automatic white
balance. It implements an
algorithm that finds possible gray
areas in the Bayer data.
Steps:
1. Click Analog Control > Balance White Auto.
2. Select Off as Balance White Auto.
3. Select Balance Ratio Selector and Balance Ratio according to actual demands
Figure 10-19 Set White Balance
Balance Ratio Selector and Balance Ratio will be invalid when selecting Once or Continuous as
Balance White Auto.
When selecting Continuous as Balance White Auto, you can set AWB (Automatic White Balance)
Color Temperature Mode, as shown below.
Steps:
1. Click Analog Control > Balance White Auto.