CA/CE-Series GigE Area Scan Camera·User Manual
72
Current
Parameter
User
Parameter 1
User
Parameter 2
User
Parameter 3
Device
Default
Parameter
load
save
load
Figure 11-2 Parameter Relation
You can save parameters, load parameters and set user default as shown below.
Save Parameters
Steps:
1. Click User Set Control, and select a user set in User Set Selector. Here we take selecting User
Set 1 as an example.
2. Click Execute in User Set Save to save parameters.
Figure 11-3 Save User Set
Load Parameters
Steps:
1. Click User Set Control, and select a user set in User Set Selector. Here we take selecting User
Set 1 as an example.
2. Click Execute in User Set Load to load parameters to the camera, as shown below.