VC3000Pro Series Vision Controller User Manual
13
PNP Device
Signal Ground
Signal Cable
R
VCC
Power Supply
DI_COM
DI1
Figure 4-3 Connect to PNP Device
NPN Device
When connecting the main module to NPN device, it is recommended to use 4.7 pull-up resistor.
NPN Device
Signal Ground
Signal Cable
R
VCC
Power Supply
DI_COM
DI1
Figure 4-4 Connect to NPN Device
Opto-Isolated Output Wiring
The opto-isolated output of the main module can output NPN or PNP signal. Regarding opto-isolated
output, different output electrical level types correspond to varied voltage ranges.
Note
When the main module's output connects external devices, the voltage range of EXT is from 7 V to
24 V, and the output current of each pin cannot be larger than 40 mA.
When the output electrical level type is high electrical level, the voltage range is from EXT-0.3 V
to EXT voltage value.
When the output electrical level type is low electrical level, the voltage range is from 0 V to 0.4 V.