EasyManua.ls Logo

HIKVISION DS-19S08N-04F/K Series

HIKVISION DS-19S08N-04F/K Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Video Security Control Panel User Manual
--41--
Local Port Number Settings 3.1.10
The programming commands of local port number setting are as below:
474 0 8 0 0 0 #
1 2
4
63 5
7
{1} The programming command address of local port number setting is: 474;
{2} Port: Ten Thousands’ Digit
{3} Port: Thousands’ Digit
{4} Port: Hundreds’ Digit
{5} Port: Tens’ Digit
{6} Port: Digit
{7} End the command.
Corresponding port number must be 5 bytes. When the place is not sufficient, fill it up with 0.
For example: When the port number is 6000, the programming command is: 474 06000#.
Sub-net Mask Settings 3.1.11
The programming commands of control panel sub-net mask setting are as below:
475 255 255 255 000 #
1
2 4 63 5
{1} The programming command address of control panel sub-net mask setting is 475;
{2} The First Unit;
{3} The Second Unit;
{4} The Third Unit;
{5} The Fourth Unit;
{6} End the command.

Table of Contents