Video Security Control Panel User Manual
--78--
Stay Arming 3.2.3
Operation Method: {User password} + {*} + {4} + {#}.Take the password 1234 as an example, and the operation is
shown as follows:
{1} + {2} + {3} + {4} + {*} + {4} + {#}
After the operation is completed, the partition will change the status of disarming (current status) into arming
immediately. The bypass-supported zone of the partition will do auto-bypass simultaneously.
Zone Bypass/Recovery 3.2.4
After bypassing a zone, all the alarm devices in this zone will be blocked. ; see the command below
{User password} + {bypass} + {zone Number} + {#}
For continuous bypass/ recovery; see the command below:
1234 1
Bypass
#
+
+
+
2Bypass #
++
Bypass
#
++
8
……
15 Seconds
Continuous operation of multi-zone bypass/ recovery should be completed within 15 seconds
Group Bypass 3.2.5
After a partition is conducted with group bypass, all the alarm devices in group-bypass supported zone of the
partition will be blocked. See the command below.
{User Password} + {*} + {4} + {1} + {#}
Group Bypass Recovery 3.2.6
After recovering the group bypass of a partition, all the alarm devices in group-bypass supported zone of the
partition will be re-validated. See the command below.
{User Password} + {*} + {4} + {2} + {#}