Video Security Control Panel User Manual
--50--
{1} The programming command address of control panel tamper-proof disconnecting linkage siren is:
511;
{2} It indicates whether to link the siren or not;
Command
Description
Command
Description
0
Not link the Siren
1
Link the Siren
{3} End the command.
Testing Report Settings 3.1.25
The testing report is used to validate the communication of control panel and alarm center. The detailed
operation is show as follows.
513 0 1 5 #
1 2 3 54
{1} Testing Report Programming Address: 513
{2} Enable/Disable the testing report
Command
Command Description
Command
Command Description
0
Disable
1
Enable
{3} Timer of the testing report. It indicates the time of firstly sending the test report. The initial value is
the time of enabling the test report.
Command
Command Description
Command
Command Description
0
1/4H
4
3H
1
1/2H
5
4H
2
1H
6
6H
3
2H
7
8H
8
10H
*2
18H
9
12H
*3
20H