Video Security Control Panel User Manual
{1} Non-zone Alarm Report Settings Command Address: 680.
{2} It indicates the white list number. 01~08 indicate white list No.1~No.8.
{3} It indicates to enable/disable the Non-zone Alarm Report.
{4} Soft zone Report
{5} System Status Report
{6} Alarm Clearing Report
{7} Testing Report
{8} Arming Report
{9} Disarming Report
{10} Control Panel Duress Report
{11} Alarm Recovery Report
{12} Bypass Report
{13} Bypass Recovery Report
{4}~{13} set the value as 1 to send the report. Set the value as 0 not to send the report.
{14} End the command.
Partition Arming Permission Settings
To configure the permission of partition arming, please refer to the command below.
681 00 0 0 0 0 0 0 0 0 #
1
2 4 63 5
87
9
10
11
{1} Partition Arming Permission Settings Command Address: 681
{2} It indicates the white list number. 01~08 indicate white list No.1~No.8.
{3} The Arming Permission of Partition 1
{4} The Arming Permission of Partition 2
{5} The Arming Permission of Partition 3
{6} The Arming Permission of Partition 4
{7} The Arming Permission of Partition 5