Detecon Funcon Parameter Descripon
The higher the value is, the more easily the
re source of lower temperature can be
detected, and the higher the false alarm
rate is.
Smoke Detecon Display Smoke Source Frame on Stream
Display a red frame around the smoke
source on stream when smoke occurs.
Sensivity
The higher the value is, the more easily the
smoke can be detected, and the higher the
false alarm rate is.
Vericaon Sensivity
The higher the value is, the more quickly
the device can double-check and idenfy
the smoke, and the higher the false alarm
rate is.
Note
Smoke Detecon is not supported when Day/Night Switch mode is Night or when the device
idenes the environment as night.
5.
Oponal: Go to Smart Event → Smoke Detecon Shield . You can shield certain areas from
being detected in smoke detecon, refer to .
6.
Refer to
Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
7.
Click Save.
4.2.3 Set Dynamic Fire Source
Detecon
To avoid the potenal re damage, you can congure the re detecon funcon for certain areas.
The detail
conguraon steps show as below.
Steps
1.
Go to Conguraon → Local .
2.
Check Locate Highest Temperature Point to display the posion of highest temperature. Check
Frame Fire Point to frame the
re source on live view.
3.
Go to Conguraon → Event → Smart Event , select Dynamic Fire Source Detecon.
4.
Check Enable Dynamic Fire Source
Detecon.
5.
Set the parameters of re detecon.
Fire Source Detecon
Thermal Opcal Bi-spectrum Network Camera User Manual
28