Do you have a question about the HIMA HIMatrix F3 AIO 8/4 01 and is the answer not in the manual?
Model | F3 AIO 8/4 01 |
---|---|
Input Channels | 8 |
Output Channels | 4 |
Product type | Safety Controller |
SIL level | SIL 3 |
Safety Integrity | SIL 3 |
Number of digital inputs | 8 |
Number of digital outputs | 4 |
Manufacturer | HIMA |
Inputs | 8 digital inputs |
Outputs | 4 digital outputs |
Details the organization of the manual and system variants for programming tools.
Identifies system planners, engineers, programmers, and maintenance personnel.
Explains the use of bold, italics, and courier fonts, and special markers for notes.
Describes the design of HIMatrix components for safety-related controller systems.
Covers ambient temperature, pollution, altitude, and ESD protective measures.
Discusses potential risks from faults and general safety precautions.
Explains the site's safe state if a device or module fails during an emergency.
Details the 8 safety-related analog inputs, their specifications, and fault reactions.
Describes the 4 analog outputs, their safety use, and output values.
Lists available model variants, part numbers, and scope of delivery.
Explains the assembly, block diagram, and function of the device's LEDs.
Covers Ethernet connections, properties, and network ports used for communication.
Provides general product data, analog input/output specifications, and variant details.
Lists certifications like CE, TÜV, UL, FM approvals and relevant standards.
Instructions for mounting the remote I/O on DIN rails or mounting plates.
Details terminal assignments for connecting analog inputs and outputs.
Lists available shunt adapter models and their part numbers for analog inputs.
Specific conditions and labels for mounting the F3 AIO 8/4 01 in Zone 2.
Guide to configuring the remote I/O using the SILworX programming tool.
Guide to configuring the remote I/O using the ELOP II Factory programming tool.
Describes proper wiring for safety-related applications, including proximity switches.
Explains that the remote I/O operates with a controller and requires no specific handling.
Details how to diagnose issues using LEDs and the programming tool.
Covers fault identification, maintenance measures, OS loading, and proof testing.
Instructions for removing the device, including disconnecting cables.
Guidelines for safely transporting HIMatrix components in their original packaging.
Information on industrial responsibility for ecologically sound disposal of hardware.
Provides definitions for technical terms used throughout the manual.
Lists all figures and tables with their corresponding page numbers.
An alphabetical index to quickly locate specific topics within the document.