8.6 Message Reference
122
Device-Specific Commands
Set and Query Device-Specific Event Status Enable Registers ESER0
Syntax
Command
:ESE0 <0 to 255>
Query
:ESE0?
Response <0 to 255 (NR1)>
Description
Command Sets the mask pattern in Event Status Enable Register 0 (ESER0) for
the Event Status Register.
Query Queries the mask pattern in Event Status Enable Register 0 (ESER0)
for the Event Status Register.
Note
Data initializes to zero at power-on.
1286432168421
bit 7bit 6bit 5bit 4bit 3bit 2bit 1bit 0
unused unused
ERR
unused unused unused
INDEX EOC
Set and Query Device-Specific Event Status Enable Registers ESER1
Syntax
Command
:ESE1 <0 to 255>
Query
:ESE1?
Response <0 to 255 (NR1)>
Description
Command Sets the mask pattern in Event Status Enable Register 1 (ESER1) for
the Event Status Register.
Note
Data initializes to zero at power-on.
1286432168421
bit 7bit 6bit 5bit 4bit 3bit 2bit 1bit 0
FAIL
AND V-Hi V-IN V-Lo R-Hi R-IN R-Lo
Read Device-Specific Event Status Registers ESR0 and ESR1
Syntax
Query
:ESR0?
:ESR1?
Response <0 to 255 (NR1)>
Note
Executing :ESR0? clears the contents of ESR0.
Executing
:ESR1? clears the contents of ESR1.