91
Accuracy Table
14
Frequency (Hz)
(In the case of ACV, DC+ACV, ACµA, ACmA, or ACA)
Range Accuracy
99.999 Hz ±0.005% rdg. ±3 dgt.
999.99 Hz ±0.005% rdg. ±3 dgt.
9.9999 kHz ±0.005% rdg. ±3 dgt.
99.999 kHz ±0.005% rdg. ±3 dgt.
*1
500.00 kHz ±0.005% rdg. ±3 dgt.
*1
*1: Measurement range where the accuracy is specied in the range of
99.999 kHz/500.00 kHz
Up to 200 kHz for ACV or ACµA
Up to 50 kHz for DC+ACV
Up to 100 kHz for the range from 60.000 mV AC to 600.00 mV AC
Up to 30 kHz for ACmA or ACA
Measurement
range
0.5 Hz or more ([-----] appears for less than 0.5 Hz.)
Pulse width 1 µs or more (duty ratio: 50%)
With the lter ON, the accuracy is specied in 100 Hz or less.
During DC+ACV measurement, it is in accordance with the attenuator range
where the input component is large.