Appendix 2 Recording Intervals and Maximum Recording Times
A2
The recording time is calculated according to the recording capacity.
Up to 60,000 temperature and humidity values can be recorded.
Up to 15,000 temperature and humidity values can be recorded.
Battery life depends on the recording interval.
The following table shows battery life when power sav
ing (p.31) is enabled. Battery
life is approximately 20 days when power saving is disabled or when the statistical
recording mode is enabled.
Appendix 2 Recording Intervals and Maximum
Recording Times
The maximum recording time is limited by the remaining battery capacity.
Instantaneous Recording
Recording Interval Recording Time Recording Interval Recording Time
1 sec. 16 h, 40 min 1 min 41 d, 16 h
2 sec. 1 d, 9 h, 20 min 2 min
83 d, 8 h
5 sec. 3 d, 11 h, 20 min 5 min 208 d, 8 h
10 sec. 6 d, 22 h, 40 min 10 min
416 d, 16 h
15 sec. 10 d, 10 h 15 min 625 d
20 sec. 13 d, 21 h, 20 min 20 min
833 d, 8 h
30 sec. 20 d, 20 h 30 min 1250 d
60 min 2500 d
Statistical Recording
Recording Interval Recording Time Recording Interval Recording Time
1 sec. (can not be set) - 1 min 10 d, 10 h
2 sec. 8 h, 20 min 2 min
20 d, 20 h
5 sec. 20 h, 50 min 5 min 52 d, 2 h
10 sec. 1 d, 17 h, 40 min 10 min
104 d, 4 h
15 sec. 2 d, 14 h, 30 min 15 min 156 d, 6 h
20 sec. 3 d, 11 h, 20 min 20 min
208 d, 8 h
30 sec. 5 d, 5 h 30 min 312 d, 12 h
60 min 625 d
Appendix 3 Battery Life Approximation
Recording Interval Battery Life Recording Interval Battery Life
1 sec. to 30 sec. Approx. 20 days 1 min Approx. 3 months
10 min or more Approx. 1 year