A convenient method to monitor digital inputs (DI) and digital outputs (DO) is utilizing the
iTOOL5 or iFLASH terminal function. At the flashing command prompt press and hold “Ctrl”
and “A” to enter the RTOS (an asterisk will display). Type “digshow” and press “Enter”. The
result should be the screen shown below. The inputs and outputs are counted from right to
left and top to bottom as illustrated below.
*digshow (RTOS command to display digital inputs and outputs)
T E S T D E R D I G I T A L - E I N - U N D A U S G A E N G E
=======================================================================
Baugr. | Port | Modus | IN-Wert | IN-Wert | OUT-Wert | OUT-Wert | Status
| :Taste | | (Hex) | (Bin) | (Hex) | (Bin) | =NoLoad
-------|--------|--------|---------|----------|----------|----------|--------
Basis | 0 : 1 | NORMAL | 00 | 00000000 | 05 | 00000101 | 0000-1
Basis | 1 : 2 | NORMAL | 00 | 00000000 | 82 | 10000010 | 0011-0
Basis | 2 : 3 | NORMAL | 98 | 10011000 | 00 | |
Erw. | 0 : 4 | NORMAL | 00 | 00000000 | 00 | 00000000 | 1111-1
Erw. | 1 : 5 | NORMAL | 00 | 00000000 | 00 | 00000000 | 1111-1
Erw. | 2 : 6 | NORMAL | 00 | 00000000 | 00 | 00000000 | 1111-1
-------|--------|--------|---------|----------|----------|----------|--------
Baugruppencodierung Basis : 0F = 00001111
Baugruppencodierung Erweiterung: FF = 11111111
Hubendschalter UNTB/OFFEN/OK/KURZ: 0000
X:Exit Blank:Redraw S:Slow F:Fast
Other methods to determine digital input and output states is by probing the junction box
mounted on the rear of the cab, the C.U. 70-pass connector pins (X2), or specific resistors on
the main board, or terminal strip in the. See table above and sketches below. Be cautious
not to short the probe across connector pins.
Junction Box Assy located on rear exterior of cab