Page #137 background image
Synchronizing the System Time in the
Network
UM Basic Configuration L3P
Release
7.1
12/2011
7.3
Precision Time Protocol
137
7.3.2 Preparing the PTP Configuration
After the function is activated, the PTP takes over the configuration
automatically. The delivery settings of the device are sufficient for most
applications.
To get an overview of the time distribution, draw a network plan with all
the devices participating in PTP.
Note: Connect all the connections you need to distribute the PTP information
to connections with an integrated time stamp unit (RT modules).
Devices without a time stamp unit take the information from the PTP and use
it to set their clocks. They are not involved in the protocol.
Enable the PTP function on all devices whose time you want to
synchronize using PTP.
Select the PTP version and the PTP mode. Select the same PTP version
for all the devices that you want to synchronize.