Network Load Control
158
8.2
Multicast Application
UM Basic Configuration L3P
Release
7.1
12/2011
Parameter Values
The parameters
Max. Response Time,
Send Interval and
Group Membership Interval
have a relationship to one another:
Max. Response Time < Send Interval < Group Membership Interval.
If you enter values that contradict this relationship, the device then
replaces these values with a default value or with the last valid values.
Multicasts
With these frames you can enter global settings for the Multicast
functions.
Prerequisite: The IGMP Snooping function is activated globally.
Parameter Protocol Version Value Range Default Setting
Max. Response Time 1, 2
3
1-25 seconds
1-3,598 seconds
10 seconds
Send Interval 1, 2, 3 2-3,599 seconds 125 seconds
Group Membership Interval 1, 2, 3 3-3,600 seconds 260 seconds
Table 12: Value range for Max. Response Time, Send Interval and Group
Membership Interval