EasyManua.ls Logo

Hirschmann PowerMICE - Monitoring the Fan

Hirschmann PowerMICE
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Diagnosis
222
9.3
Out-of-band Signaling
UM Basic Configuration L3P
Release
7.1
12/2011
9.3.4 Monitoring the Fan
Devices in the Mach 4000 family have a replaceable plug-in fan unit. This
plug-in fan helps considerably in reducing the internal temperature of the
device.
Fans are subject to natural wear. The failure of one or more fans in the plug-
in fan can have a negative effect on the operation and life span of the device,
or can lead to a total failure of the device.
The device enables you
to signal changes to the status of the plug-in fan out-of-band (outside the
data flow) via a signal contact (see on page 219 “Monitoring the Device
Status via the Signal Contact”)
to signal changes to the status of the plug-in fan by sending a trap when
the device status changes
to detect status changes to the plug-in fan in the Web-based interface on
the system side and
to query changes to the status of the plug-in fan in the Command Line
Interface.