EasyManua.ls Logo

Hirschmann PowerMICE - Page 214

Hirschmann PowerMICE
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Diagnosis
214
9.1
Sending Traps
UM Basic Configuration L3P
Release
7.1
12/2011
The events which can be selected are:
Name Meaning
Authentication The device has rejected an unauthorized access attempt (see the Access
for IP Addresses and Port Security dialog).
Link Up/Down At one port of the device, the link to another device has been established/
interrupted.
Spanning Tree The topology of the Rapid Spanning Tree has changed.
Chassis Summarizes the following events:
– The status of a supply voltage has changed (see the System dialog).
– The status of the signal contact has changed.
To take this event into account, you activate “Create trap when status
changes” in the Diagnostics:Signal Contact 1/2 dialog.
- The AutoConfiguration Adapter (ACA), has been added or removed.
- The configuration on the AutoConfiguration Adapter (ACA) does not
match that in the device.
– The temperature thresholds have been exceeded/not reached.
– A media module has been added or removed (only for modular devices).
– The receiver power status of a port with an SFP module has changed
(see dialog Diagnostics:Ports:SFP Modules).
The redundancy status of the ring redundancy (redundant line active/
inactive) or (for devices that support redundant ring/network coupling) the
redundant ring/network coupling (redundancy exists) has changed.
Port security On one port a data packet has been received from an unauthorized
terminal device (see the Port Security dialog).
Table 26: Trap categories

Table of Contents

Other manuals for Hirschmann PowerMICE

Related product manuals