Entering the IP Parameters
42
2.5
System configuration via BOOTP
UM Basic Configuration L3P
Release
7.1
12/2011
switch_01:ht=ethernet:ha=008063086501:ip=10.1.112.83:tc=.global:
switch_02:ht=ethernet:ha=008063086502:ip=10.1.112.84:tc=.global:
.
.
Lines that start with a ‘#’ character are comment lines.
The lines under “.global:” make the configuration of several devices easier.
With the template (tc) you allocate the global configuration data (tc=.global:)
to each device .
The direct allocation of hardware address and IP address is performed in the
device lines (switch-0...).
Enter one line for each device.
After ha= enter the hardware address of the device.
After ip= enter the IP address of the device.
In the appendix under “Setting up a DHCP/BOOTP Server” on page 272, you
will find an example for the configuration of a BOOTP/DHCP server.