Loading/saving settings
UM Basic Configuration L3P
Release
7.1
12/2011
3.2
Saving settings
65
Note: After you have successfully saved the configuration on the device, the
device sends an alarm (trap) hmConfigurationSavedTrap together with
the information about the AutoConfiguration Adapter (ACA), if one is
connected. When you change the configuration for the first time after saving
it, the device sends a trap hmConfigurationChangedTrap.
Note: The device allows you to trigger the following events when the
configuration stored on the ACA does not match the configuration on the
device:
send an alarm (trap) (see on page 213 “Configuring Traps”),
update the device status (see on page 216 “Configuring the Device
Status”),
update the status of the signal contacts (see on page 219 “Controlling the
Signal Contact”).
Skip ACA21 during the boot phase
The device allows you to skip the ACA21 AutoConfiguration Adapter (if
connected) during the boot phase. In this case, the device ignores the
ACA21 during the boot phase. This shortens the boot phase of the device
by 1 to 4 seconds. If you have enabled this function, ACA21-functionality
becomes available as usual after the boot phase. The device simply skips
the ACA21-loading procedures during the boot phase.
enable Switch to Privileged EXEC mode.
configure Switch to Global Configure mode.
#boot skip-aca-on-boot
enable
Skip ACA21 during the boot phase. (Disabled in the as-
delivered state).
#boot skip-aca-on-boot
disable
Include the ACA21 during the boot phase.
#show boot skip-aca-
on-boot
Show whether the "Skip ACA21 during boot phase"
function is enabled.