Configuring the Ports
UM Basic Configuration L3P
Release
7.1
12/2011
85
Switch on PoE power supply
OCTOPUS PoE devices let you switch on the PoE power supply before
loading and starting the software. This means that the connected PoE
devices (powered devices) are supplied with the PoE voltage more
quickly and the start phase of the whole network is shorter.
Cold start with detected errors
This function lets you reset the device automatically with a cold start in the
following cases:
if an error is detected
(selftest reboot-on-error enable)
or
only if a serious error is detected
(selftest reboot-on-error seriousOnly)
If the function selftest reboot-on-error seriousOnly is
enabled, the device behaves as follows:
If an error is detected in a subsystem (for example, if an HDX/FDX
mismatch is detected on a port), cold starts of the device are dropped.
However, if an error affecting the function of the entire device is
detected, the device still carries out a cold start.
The device sends an alarm message (for Trap messages, see
page 210)
Note: If the selftest reboot-on-error seriousOnly function is
enabled and the device detects an HDX/FDX mismatch, automatic cold
starts of the device are dropped. In this case, to return the affected port(s)
to a usable condition, open the Basic Settings:Reboot dialog and
carry out a cold start of the device.
enable Switch to Privileged EXEC mode.
configure Switch to Global Configure mode.
#inlinepower fast-startup
enable
Switch on Inline Power Fast Startup (disabled in
the as-delivered state).
#inlinepower fast-startup
disable
Switch off Inline Power Fast Startup.
#show inlinepower Show Power over Ethernet System Information
(Fast Startup and other information).
enable Switch to Privileged EXEC mode.
configure Switch to Global Configure mode.