Item
Effect when checked (locked out)
Internal Datalog
Does not allow the user to record or play back a locally recorded logfile.
Screen 1-4 Edit
Does not allow the user to change the first four layout screen on the
dashboard. Screens 5-10 are still editable.
Screen Edit/Customization
No screens can be edited or customized.
ECU Log
The user cannot download log files from the ECU.
ECU Tuning
The ECU Tuning menu is disabled
ECU Global
Upload/Download
Global .hefi files cannot be uploaded or download to/from the ECU.
Firmware Update
The firmware cannot be updated on the unit.
File Util
File utilities menu is disabled
Backup/Restore
Dash backup and restore functionality is disabled
Standalone Choice
The user cannot switch between standalone and EFI-connected mode.
Dash Configuration
The user cannot change the local dash channel configuration, can device
configuration, vehicle settings, or touchscreen calibration.
Odometer Source
The odometer source cannot be changed.
Once you have changed the options, click on the password box and enter a password to protect the option
selections. The password is not echoed on the screen. You must confirm the password before you are
allowed to save the selections.
If the options are greyed out, you will need to enter the password before you can change the options.