3. Process Insertion
Corrosion models
34 OneWireless XYR 6000 Transmitters Quick Start Guide Revision 12
February 2013
Location Picture
Located in Tee
Probe can be located at any point on
the pipeline but should always be
immersed in the corrosive material.
Located in Bypass Loop
Probe should be located downstream
of a control valve for best performance
and can also be located in the deadleg
portion of a by-pass.
Note that the probe located in the by-
pass leg should be mounted before
the valve for best performance. This
guarantees the electrodes will always
be immersed in the corrosive material.
Mounted with Different Electrodes
Installing with different electrode
materials on the suction side of the
pump will ensure monitoring of the
pump impeller and the pipe.
Installed in a Condensate Flash Tank
A condensate flash tank is also a good
application.